FixVault

Visual/Physical Inspection

  1. Visually/physically inspect the following items:
    • Ensure that the HO2S is securely installed.
    • Check for corrosion on terminals.
    • Check for terminal tension (at the HO2S and at the ECM).
    • Check for damaged wiring.
    • Check the HO2S ground circuit for a good connection.
  2. Check front and rear HO2S for connections being reversed. If HO2S connections reversed, switch connections properly.
  3. Was a problem found in any of the above areas?

    YES: 

    NO: