FixVault

Signal Circuit Inspection

  1. Check Voltage
    1. IG "OFF" and disconnect Fuel Sender & Fuel Pump Motor connector.
    2. IG "ON" & ENG "OFF"
    3. Measure voltage between terminal 4 of Fuel Sender & Fuel Pump Motor harness connector and chassis ground.

      Specification: Approx. 12V

    4. Is the measured voltage within specification?

      YES 

      • Go to " 2 Check short to ground in harness" procedure.

      NO 

  2. Check short to ground in harness
    1. IG "OFF" and disconnect Fuel sender & Fuel pump motor connector and PCM connector.
    2. Measure resistance between terminal 6 of Fuel sender & Fuel pump motor harness connector and chassis ground.

      Specification: Infinite

    3. Is the measured voltage within specification?

      YES 

      • Go to " 3 Check open in harness" as follows.

      NO 

  3. Check open in harness
    1. IG "OFF" and disconnect Fuel sender & Fuel pump motor connector and PCM connector.
    2. Measure resistance between terminal 6 of Fuel sender & Fuel pump motor connector and terminal 30 of PCM harness connector.

      Specification: Below 1Ω

    3. Is the measured voltage within specification?

      YES 

      NO