FixVault

Control Circuit Inspection

  1. Measure the voltage between terminal 86 of the fuel pump relay harness connector and chassis ground.

    Specification : 4~5V

    Fig 1: Measuring Voltage Between Terminal 86 Of Fuel Pump Relay Harness Connector And Chassis Ground
    G05363828
  2. Is voltage within the specification?

    YES 

    • Go to next step as below

    NO