FixVault

Signal Circuit Inspection

  1. Check Voltage
    1. IG "OFF" and disconnect FLS connector.
    2. IG "ON" & ENG "OFF"
    3. Measure voltage between terminal 3 of FLS harness connector and chassis ground.

      Specification: Approx. 11.46V

    4. Is the measured voltage within specification?

      YES 

      NO 

      • Go to " 2Check short to ground in harness" as follows
  2. Check short to ground in harness
    1. IG "OFF" and disconnect FLS connector.
    2. Measure resistance between terminal 3 of FLS harness connector and chassis ground.

      Specification: Infinite

    3. Is the measured resistance within specification?

      YES 

      • Go to " 3Check open in harness" procedure.

      NO 

  3. Check open in harness
    1. IG "OFF" and disconnect FLS connector and PCM connector.
    2. Measure resistance between terminal 3 of FLS harness connector and terminal 29 of PCM harness connector.

      Specification: Approx. Below 1Ω

    3. Is the measured resistance within specification?

      YES 

      NO