FixVault

Ground Circuit Inspection

  1. Ignition "OFF"
  2. Disconnect OTS connector
  3. Measure resistance between terminals 1 of the OTS harness connector and chassis ground

    Specification:  Approx. 0Ω

  4. Is resistance within specification?

    YES 

    NO