Control Circuit Inspection

  1. Measure voltage between terminal 6 of the CCV harness connector and chassis ground

    Specification:  Approx. 4~5V

    Fig 1: Measuring Voltage Between Terminal 6 Of CCV Harness Connector And Chassis Ground
    G00486624Courtesy of HYUNDAI MOTOR CO.
  2. Is voltage within the specification?

    YES 