FixVault

ECU Connector Input/Output (ABS): Notes

Fig 1: ECU Connector Input/Output (ABS) Terminals
G05364963Courtesy of HYUNDAI MOTOR CO.
ECU CONNECTOR REFERENCE

Wire No. Designation Current max. permissible wire resistance R L (mΩ) min. leakage resistance R P (kΩ)
max min
1 Ground for recirculation pump 20~39 A 10A 10  
4 Ground for solenoid valves and ECU 5~15 A 2.5 A 10  
2 Voltage supply for pump motor 20~39 A 10A 10 200
3 Voltage supply for solenoid valves 5~15 A 2A 10 200
18 Voltage for hybrid ECU 1 A 500 mA 60 200
5,10,17,19 signal wheel speed sensor FL, FR, RL, RR 16 mA 6mA 250 200 to ground 1.5Mtobat
16,9,6,8 Voltage supply for the active wheel speed sensor FL, FR, RL, RR 10 mA 6 mA 250 200 to ground 1.5Mtobat
11 Diagnostic wire K 6mA 3mA 250 200
22 ABS-warning lamp actuation 30 mA 5 mA 250 200
12 EBD-warning lamp actuation 30 mA 5 mA 250 200
20 brake light switch 10 mA 5mA 250 200
15 CAN Low 30 mA 20 mA 250 200
26 CAN High 30 mA 20 mA 250 200