Function and operation principle

Variable Intake manifold Solenoid (VIS) valve is installed on the intake manifold. The VIS valve controls the vacuum modulator which activates a valve in the intake manifold. The PCM opens or closes this valve according to engine condition (Refer to below table).

Fig 1: Identifying Variable Intake Solenoid Valve Location
G06107529Courtesy of HYUNDAI MOTOR CO.
ENGINE CONDITION OPERATION CHART

Engine condition VIS valve Operation
Medium speed Closed Increasing engine performance in low engine speed by reducing intake interference among cylinders
Low/High speed Open Minimizing intake resistance by shortening intake manifold length and increasing area of air entrance
Fig 2: Identifying Variable Intake Solenoid Valve
G06107530Courtesy of HYUNDAI MOTOR CO.