FixVault

HO2S Fuse Inspection

  1. Ignition "OFF" & Engine "OFF"
  2. Verify "10A Sensor fuse" is installed and not blown.
  3. If OK, go to "COMPONENT INSPECTION " procedure.

    If NG, replace fuse and repair any shorts as necessary and go to "VERIFICATION OF VEHICLE REPAIR " procedure.