FixVault

Hydraulic Pressure Test

  1. Warm up the engine until the automatic transaxle fluid temperature is 80~100°C.
  2. Jack up the vehicle so that the wheels are free to turn.
  3. Connect the special tool (oil pressure gauge) to each pressure discharge port.
  4. Measure the hydraulic pressure at each port under the conditions given in the standard hydraulic pressure table, and check that the measured values are within the standard value ranges.
  5. If a value is outside the standard range, correct the problem while referring to the HYDRAULIC PRESSURE TEST DIAGNOSIS TABLE .
    Fig 1: Identifying Special Tool (1 Of 3)
    G04811225Courtesy of HYUNDAI MOTOR CO.
    Fig 2: Identifying Special Tool (2 Of 3)
    G04811226Courtesy of HYUNDAI MOTOR CO.
    Fig 3: Identifying Special Tool (3 Of 3)
    G04811227Courtesy of HYUNDAI MOTOR CO.

Standard Hydraulic Pressure Test 

STANDARD HYDRAULIC PRESSURE TEST

Measurement condition Standard hydraulic pressure kPa (psi)
Selector lever position Shift position Engine speed (rpm) Under drive clutch pressure Reverse clutch pressure Overdrive clutch pressure Low and reverse brake pressure Second brake pressure Torque converter pressure
P - 2,500 - - - 310-390 (45~56) - 250-350 (36-56)
R Reverse 2,500 - 1,270-1,770 (185-256) - 1,270-1,770 (185-256) - 500-700 (185-256)
N 2,500 - - - - 310-390 (45-56) - 250-390 (36-56)
D 1st gear 2,500 1,010-1,050 (146-152) - - 1,010-1,050 (146-152) - 500-700 (73-101)
2nd gear 2,500 1,010-1,050 (146-152) - - - 1,010-1,050 (146-152) 500-700 (73-101)
3rd gear 2,500 590-690 (85-100) - 590-690 (85-100) - - 450-650 (65-94)
4th gear 2,500 - - 590-690 (85-100) - 590-690 (85-100) 450-650 (65-94)

* The values are subject to change according to vehicle model or condition