FixVault

Signal Circuit Inspection

  1. Check voltage
    1. IG "OFF" and disconnect IATS connector.
    2. IG "ON" and ENG "OFF"
    3. Measure voltage between terminal 4 of IATS harness connector and chassis ground.

      Specification:  Approx. 5V

      Fig 1: Measuring Voltage Between Terminal 4 Of IATS Harness Connector And Chassis Ground
      G06804409Courtesy of HYUNDAI MOTOR CO.
    4. Is the measured voltage within specification?

      YES 

      NO 

      • Go to " 2 Check short to ground in harness" procedure.
  2. Check short to ground in harness
    1. IG "OFF" and disconnect IATS connector and PCM connector.
    2. Measure resistance between terminal 4 of IATS harness connector and chassis ground.
    3. Measure resistance between terminals 4 and 5 of IATS harness connector.
    4. Measure resistance between terminals 4 and 3 of IATS harness connector.

      Specification:  Infinite

      Fig 2: Measuring Resistance Between Terminal 4 Of IATS Harness Connector And Chassis Ground
      G06804410Courtesy of HYUNDAI MOTOR CO.
      Fig 3: Measuring Resistance Between Terminals 4 And 5 Of IATS Harness Connector
      G06804411Courtesy of HYUNDAI MOTOR CO.
    5. Is the measured resistance within specification?

      YES 

      NO