FixVault

Repair procedures (A4CF2): Adjustment

Adjusting method for the control cable

  1. Set room side lever and T/M side lever (A) to "N" position.
  2. Connect the room side lever and shift cable. (refer to 'INSTALLATION ')
  3. Connect the T/M side lever (A) to cable (B) in this following order;
    1. Push the cable (B) lightly to "F" direction shown in illustration to eliminate FREE PLAY of the cable (B).
    2. Tighten the adjusting nut (C).
      Fig 1: Adjusting Control Cable
      G06863416Courtesy of HYUNDAI MOTOR CO.
  4. After adjusting the cable (B) according to procedure no. 2-3, check to be sure that this part operates surely at each range of T/M side corresponding to each position of room lever.