FixVault

Inspect Charging System: Preparation

  1. Turn the ignition switch to "OFF".
  2. Disconnect the output wire from the alternator "B" terminal. Connect the (+) lead wire of ammeter to the "B" terminal of alternator and the (-) lead wire of ammeter to the output wire. Connect the (+) lead wire of voltmeter to the "B" terminal of alternator and the (-) lead wire of voltmeter to the (+) terminal of battery.
Fig 1: Connecting (+) Lead Wire Of Voltmeter To "B" Terminal Of Alternator And (-) Lead Wire Of Voltmeter To (+) Terminal Of Battery
G06801617Courtesy of HYUNDAI MOTOR CO.