Transmitter Code Registration (Using Code Saver)
- Open Door.
- Connect POWER (B+) and GND, signal line of Code Saver.
- If connection is normal, signal line is activated and RED LED turns ON.
- If switch of Code Saver turns ON, data via signal line will be transmitted.
- BCM enters into Code Save mode when it receives data from Code Saver and send Code Save Start signal via signal line.
- Code Saver turns Green LED ON when it receives Code Save Start signal.
- When you press Lock or Unlock button of transmitter, BCM will save Codes.
- If there are 2 transmitters for Code Saving, register by performing item 7).
- If switch of Code Saver turns OFF or is disconnected, Code Saving mode will be finished.
Code saving method
CODE SAVING METHOD REFERENCE
| NO | Saved code | Code to change | Changed code |
|---|---|---|---|
| 1 | A | C | C (A is deleted) |
| 2 | A, B, C, D | E | E (A, B, C, D are deleted) |
| 3 | A, B | C, D, E | C, D |
| 4 | A, B | C, C, D | C |