FixVault

Repair Procedures: Inspection

  1. Turn the ignition switch OFF.
  2. Disconnect the IATS connector.
  3. Measure resistance between the IATS terminals 4 and 5.
  4. Check that the resistance is within the specification.

    Specification:  Refer to SPECIFICATION  Section.