Repair procedures: Inspection
- Check that the red light flickers when the door lock or unlock button is pressed on the transmitter.
- Remove the battery and check voltage if the red light doesn't flicker.
Standard voltage: 3V
- Insert the battery (A) into the tester (09954-2p100).
- Push the test button and If "0.00" is displayed on screen, it means that the battery voltage is 2V or less.
- If "L" is displayed on screen, it means that the battery is low power and it needs to be replaced.
- To prevent the discharge of electricity, turn the tester power off.
- Replace the transmitter battery with a new one. If voltage is low power then try to lock and unlock the doors with the transmitter by pressing the lock or unlock button five or six times.
- If the doors lock and unlock, the transmitter is OK, but if the doors don't lock and unlock, register the transmitter code, then try to lock and unlock the doors.
- If the doors lock and unlock, the transmitter is OK, but if the doors don't lock and unlock, replace the transmitter.WARNING: An inappropriately disposed battery can be harmful to the environment and human health. Dispose the battery according to your local law(s) or regulation.