ECU Connector Input/Output (ABS): Notes

Fig 1: ECU Connector Input/Output (ABS) Terminals
G05364963Courtesy of HYUNDAI MOTOR CO.
ECU CONNECTOR REFERENCE

Wire No. Designation Current max. permissible wire resistance R L (mΩ) min. leakage resistance R P (kΩ)
max min
1 Ground for recirculation pump 20~39 A 10 A 10  
4 Ground for solenoid valves and ECU 5~15 A 2.5 A 10  
2 Voltage supply for pump motor 20~39 A 10 A 10 200
3 Voltage supply for solenoid valves 5~15 A 2 A 10 200
18 Voltage for hybrid ECU 1 A 500 mA 60 200
5, 10, 17, 19 signal wheel speed sensor FL, FR, RL, RR 16 mA 6 mA 250 200 to ground
1.5 M to bat
16, 9, 6, 8 Voltage supply for the active wheel speed sensor FL, FR, RL, RR 10 mA 6 mA 250 200 to ground
1.5 M to bat
11 Diagnostic wire K 6 mA 3 mA 250 200
22 ABS-warning lamp actuation 30 mA 5 mA 250 200
12 EBD-warning lamp actuation 30 mA 5 mA 250 200
20 brake light switch 10 mA 5 mA 250 200
15 CAN Low 30 mA 20 mA 250 200
26 CAN High 30 mA 20 mA 250 200