FixVault

Data Flow

Fig 1: ATM Shift Lock Control Moving Position
G10244017Courtesy of HYUNDAI MOTOR AMERICA
  1. In L_IGN1 ON, C_InhibitP ON or C_InhibitN ON condition, if L_BrakeSW input is ON, O_ATMSOL output is ON to makes moving condition of SHIFT LEVER.
  2. In L_IGN1 ON, vehicle speed is less than 7KPH and C_InhibitD ON conditions, if L_BrakeSW input is ON, O_ATMSOL output is ON to makes moving condition of SHIFT LEVER.
    Fig 2: ATM Shift Lock Control - Blinking Pattern
    G10244018Courtesy of HYUNDAI MOTOR AMERICA