FixVault

Electrical Performance

Item Requirement Remark
Rated voltage DC 12 V -
Operating voltage range DC 9 ~ 16 V Shall activate normally in these range
Operating temperature range -30°C ~ +80°C Shall conserve normally in these range.
Storage temperature range -40°C ~ +85°C
Max humidity in use 95% -
High voltage resistance 24 V/1 min, 18 V/1 hour After overvoltage is the Normal behavior
Insulation resistance 100 MΩ or more (measured with 500 V MEGGER) Specify as well as parts that insulation like PCB, moisture-proof COATING is required.
Quiescent current KEYLESS spec: 6 mA or less
SMK spec: 5 mA or less
NON-KEYLESS: 3 mA or less
Measure when the state, all output loads are OFF and there are no Input SW (including TX operation) changes, continues 2 sec.
Voltage drop 1.2 V or less but, Terminal C01, C02, C03, C13, C14, C16, C19, C21 is 2.0 V or less.