FixVault

Control Circuit Inspection

  1. IG "OFF" & Disconnect HO2S(S1) connector.
  2. IG "ON" & ENG "OFF".
  3. Measure voltage between control terminal of HO2S(S1) heater harness connector and chassis ground.
  4. Specification:  Approx. 3.5V

  5. Is the measured voltage within specification?

    YES 

    NO