FixVault

Signal Circuit Inspection

  1. IG "OFF" & Disconnect HO2S(S1) connector.
  2. IG "ON" & ENG "OFF".
  3. Measure the voltage between Nernst Voltage, Vertual Ground Output, Current Adjust and Current Pump terminals of HO2S(S1) harness connector and chassis ground.

    Specification:  Nernst Voltage terminal: Approx. 2-3V; Vertual Ground Output terminal: Approx. 2.5V; Current Adjust terminal: Approx. 2-3V; Current Pump terminal: Approx. 2-3V

  4. Is the measured voltage within specification?

    YES 

    • Go to COMPONENT INSPECTION  .

    NO