FixVault

Repair Procedures: Replacement

WARNING: This page is about a different variant/trim than selected.
  1. Remove the air cleaner assembly. (Refer to REMOVAL AND INSTALLATION )
  2. Disconnect the neutral position switch connector (A).
  3. Fig 1: Neutral Position Switch & Connector
    G00558268Courtesy of HYUNDAI MOTOR AMERICA
  4. Remove the neutral position switch.
  5. Replace a new one and install the neutral position switch, then connect the connector.
  6. Specification: 

    29.4 ~ 34.3 N.m (3.0 ~ 3.5 kgf.m, 21.7 ~ 25.3 lb-ft)