DTC Information: DTC Detecting Condition

Item Detecting Condition Possible cause
DTC Strategy
  • O2S signal interrupt by heater
  1. Poor connection
  2. Open or short in signal circuit
  3. B2/S2
Case1 Enable Conditions
  • Battery voltage is higher than 10.7V
  • Exhaust gas temperature (model) is higher than 700°C (1292°F)
  • O2S heater voltage is higher than 9.2V
Threshold value
  • S2 sensor voltage is between 0.4V and 0.5V
Diagnosis Time
  • 400sec
Case2 Enable Conditions
  • Battery voltage is higher than 10.7V
  • Time after dew point end detected is higher than 10 sec
Threshold value
  • The number of that the absolute value of Δusvk is greater than 2V during 0.04 sec after turning on and off a heater is more than or equal to 5 times.
MIL On Condition
  • 3 driving cycle