DTC Information: DTC Detecting Condition

Item Detecting Condition Possible Cause
DTC Strategy
  • No signal activity
  1. Poor connection
  2. Short to Power in signal circuit
  3. HO2S (B1/S2)
  4. ECM
Enable Conditions
  • Mass flow is between 20 and 120kg/h
  • Delta Mass Flow 2kg/h
Threshold Value
  • Downstream O2S voltage is higher than 0.65V for 8 sec.
  • Downstream O2S voltage is higher than 0.25V for 0.2sec(Fuel cut)
Diagnostic Time
  • -
MIL ON Condition
  • 2 Driving Cycles