FixVault

Signal Circuit Inspection

  1. IG "OFF" and disconnect HO2S (B1/S2) connector.
  2. IG "ON"
  3. Measure voltage between signal terminal of HO2S (B1/S2) harness connector and chassis ground.

    Specification:  Approx. 0.45V

  4. Is the measured voltage within specification?

    YES 

    NO