Repair procedures: Inspection

  1. After disconnecting the vapor hose from the PCV valve, remove the PCV valve.
  2. Reconnect the PCV valve to the vapor hose.
  3. Inspect the PCV valve operation.
    1. Run the engine at idle.
    2. Put a finger on the open end of the PCV valve.
    3. Make sure that intake manifold vacuum can be felt.
    NOTE: The plunger inside the PCV valve will move back and forth at vacuum.
    Fig 1: Inspecting PCV Valve Operation
    G10367328Courtesy of HYUNDAI MOTOR AMERICA
  4. If the vacuum is not felt, clean or replace the vapor hose.