FixVault

Repair Procedures: Removal

  1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
  2. Disconnect the purge control solenoid valve connector (A).
  3. Disconnect the vapor hoses (B) from the purge control solenoid valve.
  4. Remove the valve (C) from the surge tank after pulling it.
Fig 1: Identifying Purge Control Solenoid Valve Vapor Hoses And Surge Tank Valve
G10611539Courtesy of HYUNDAI MOTOR AMERICA