Repair Procedures: Inspection
[Rotor]
- Check that there is continuity between the Slip Rings (C).
- Check that there is no continuity between the slip rings and the Rotor (B) or Rotor Shaft (A).
- If the Rotor fails either continuity check, replace the Alternator.
[Stator]
- Check that there is continuity between each pair of Leads (A).
- Check that there is no Continuity between each lead and the Coil Core.
- If the Coil fails either continuity check, replace the Alternator.