FixVault

Repair Procedures: Removal

  1. Turn the Ignition Switch OFF and disconnect the Battery Negative (-) Cable.
  2. Disconnect the CVVT Oil Control Valve Connector (A).
  3. Remove the installation Bolt (B), and then remove the Valve from the Engine.

    [Bank 1/Intake] 

    Fig 1: CVVT Oil Control Valve Connector And Installation Bolt (Bank 1/Intake) Location
    G10604609Courtesy of HYUNDAI MOTOR AMERICA

    [Bank 1/Exhaust] 

    Fig 2: CVVT Oil Control Valve Connector And Installation Bolt (Bank 1/Exhaust) Location
    G10604610Courtesy of HYUNDAI MOTOR AMERICA