FixVault

System Inspection

■ Check Generator circuit 

  1. Engine starts.
  2. Maintain ENG RPM 2, 500 RPM over 2 minutes.
  3. Measure voltage between the battery terminal (+) and the battery terminal (-).

    Specification:  Approx. 12.5 ~ 14.7V

    Fig 1: Measuring Voltage Between Battery Terminal (+) And Battery Terminal (-)
    G10373985Courtesy of HYUNDAI MOTOR AMERICA
    Fig 2: Battery Sensor Circuit Terminals
    G10373986Courtesy of HYUNDAI MOTOR AMERICA
  4. Is the measured voltage within specification?

    YES 

    NO 

    • Check that the tension of drive belt, ENG RPM, fuse, terminal of battery, all terminals of generator are in good condition and Check for damaged harness and poor connection between generator and battery. If OK repair or replace generator and then go to "VERIFICATION OF VEHICLE REPAIR " procedure.