FixVault

Repair Procedures: Installation

  1. Installation is the reverse of removal.
  2. Adjust the ignition switch.
    1. In state of full stroke, adjust the gab by rotating the adjust nut (A) to satisfy the standard gap range.

      Standard Gap Range: 

      3 ~ 4 mm (0.1181 ~ 0.1575 in.)

    2. Tighten the nut (B) with the specified torque.

      Tightening Torque: 

      7.8 ~ 9.8 N (0.8 ~ 1.0 kgf.m, 5.8 ~ 7.2 lb-ft)

      Fig 1: Adjusting Ignition Switch
      G10750041Courtesy of HYUNDAI MOTOR AMERICA