FixVault

Repair Procedures: Removal

  1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
  2. Disconnect the purge control solenoid valve connector (A).
  3. Disconnect the vapor hoses (B) from the purge control solenoid valve.
    Fig 1: Identifying PCSV Connector And Vapor Hoses
    G10582820Courtesy of HYUNDAI MOTOR AMERICA
  4. Remove the valve from the bracket in the direction of the arrow.
    Fig 2: Removing Purge Control Solenoid Valve
    G10582821Courtesy of HYUNDAI MOTOR AMERICA