FixVault

Repair Procedures: Removal

  1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
  2. Remove the fuel tank.

    (Refer to "FUEL TANK ")

  3. Disconnect the fuel tank pressure sensor connector (A).
  4. Disconnect the vapor hose (B).
    Fig 1: Disconnecting Fuel Tank Pressure Sensor Connector
    G12060827Courtesy of HYUNDAI MOTOR AMERICA
  5. Remove the 2 way cup valve plate (A) after removing the bolts.
    Fig 2: Removing 2 Way Cup Valve Plate Bolts
    G12060828Courtesy of HYUNDAI MOTOR AMERICA
  6. Release the hooks and then remove the fuel tank pressure sensor from the fuel pump.