FixVault

Repair Procedures: Removal

  1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
  2. Disconnect the CVVT oil control valve connector (A).
  3. Remove the installation bolt (B), and then remove the valve from the engine.

[Bank 1/Intake] 

Fig 1: Locating CVVT Oil Control Valve (OCV) Installation Bolt - Bank 1/Intake
G11643700Courtesy of HYUNDAI MOTOR AMERICA

[Bank 1/Exhaust] 

Fig 2: Locating CVVT Oil Control Valve (OCV) Installation Bolt - Bank 1/Exhaust
G11643701Courtesy of HYUNDAI MOTOR AMERICA