Repair Procedures: Installation
- Check that the shift lever is placed in the "N" position.
- Lightly tighten the inhibitor switch mounting bolts after installing the inhibitor switch (A).
- Lightly tighten the manual control lever mounting nut after installing the manual control lever (B).
- Align the hole (B) in the manual control lever with the "N" position hole (A) of the inhibitor switch and then insert the SST inhibitor switch guide pin (09480-A3800).
- Tighten the bolts (B) after tightening the nut (A) with the specified torque.
Tightening torque:
- 17.7 ~ 24.5 N.m (1.8 ~ 2.5 kgf.m, 13.0 ~ 18.1 lb-ft)
- 9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)
- Lightly tighten the nut (B) after connected the shift cable in the manual control lever.
- Push shift cable lightly to "F" direction shown to eliminate free play of shift cable.
- Tighten the nut (B) with the specified torque.
- Connect the inhibitor switch connector (A).
Tightening torque:
9.8 ~ 13.7 N.m (1.0 ~ 1.4 kgf.m, 7.2 ~ 10.1 lb-ft)
- Remove the inhibitor switch guide pin (SST No.: 09480-A3800) from the hole.
- Install the battery and battery tray.
(Refer to "BATTERY ")
- Install the ECM.
(Refer to "ECM ")
- Install the air cleaner assembly and air duct.
(Refer to "AIR CLEANER ")
CAUTION: Check that operating surely at each range of the inhibitor switch corresponding to each position of shift lever.