FixVault

[EWGA Position Sensor]

ELECTRONIC WASTE GATE ACTUATOR (EWGA) SPECIFICATION

Position Output Voltage [V] Operating Angle [°]
Mechanical Close end stop Position (MCP) 4.62 50.6
Electrical Close end stop Position (ECP) 3.8 29.3
Electrical Open end stop Position (EOP) 1.2 323.3
Mechanical Open end stop Position (MOP) 0.42 303.6
G12977123Courtesy of HYUNDAI MOTOR AMERICA