  • When the electric E-CVVT assembly is replaced or remounted, make sure to use the additional feature menu on the KDS/GDS diagnosis equipment and reset the learned value.
  • When the learned value for electronic cam position is erased, start learning the cam position while cranking. When it is completed, engine is started.
  • Cranking should be repeated for maximum 2 to 3 for learning.
    G13035108Courtesy of HYUNDAI MOTOR AMERICA