FixVault

Component Inspection

  1. Connect a GDS to DLC (Data Link Cable).
  2. Turn the ignition switch ON.
  3. Actuate the "EGR Valve" using the GDS.

    (Check the EGR valve duty sensor data during forced actuation. Check operation sound.)

  4. Does the actuation work properly? Is the sensor output normal?

Specification:  Refer to MONITORING CURRENT DATA 

YES 

NO 

CAUTION: The learnt value must be reset after replacing the EGR valve. Otherwise, problems regarding performance and exhaust may occur until the automatic learning takes place after component replacement.