FixVault

Repair Procedures: Installation

CAUTION:
  • Because the accumulator is filled with high pressure nitrogen gas, Be sure to degas the accumulator before discarding it.
  • Discarding method: Drill the 3 mm hole in the hexagon nut (10 to 20 mm from center) to eliminate the gas using the fixed drill (hand drill is prohibited to use).
  • Wear protective equipment such as safety glasses and earplugs as metal particles may fly when gas is ejected.
  1. To install, reverse the removal procedures.
  2. After installing the accumulator, perform the procedure to release the line pressure elimination mode using the diagnostic tool.
G15474870Courtesy of HYUNDAI MOTOR AMERICA