FixVault

Feedback Position Sensor

  1. Connect the diagnostic tool to the data link connector.
  2. Perform the fully open and the fully closing operation of the EEGR valve by using the actuation test.
  3. Check that the voltage is within the specification
    • Specification 
    Item Specification
    Sensor Power (V) 5
    Opened Voltage (V) 3.85 - 4.15
    Closed Voltage (V) 0.85 - 1.15