FixVault

LAN System Improper Operation (ITB97-005)

Publication date: 1997-01-29
Reference number: ITB97-005

LAN SYSTEM IMPROPER OPERATION

LAN SYSTEM IMPROPER OPERATION

TECHNICAL SERVICE BULLETIN

Reference Number(s): ITB97-005, Date of Issue:  January 29, 1997
INFINITI: 1994-1996 Q45
CLASSIFICATION: EL97-001
SECTION: Electrical System
APPLIED VEHICLE(S): 1994-1996 Q45 (G50)

SERVICE INFORMATION

If a 1994-96 Q45 vehicle exhibits incorrect local area network (LAN) system operations, the primary symptom may be incorrect automatic drive positioner (ADP) adjustment. Other symptoms may include improper operation of:

A new body control module (BCM) has been developed to resolve these incidents. Perform the following SERVICE PROCEDURE to diagnose and repair the vehicle.

SERVICE PROCEDURE

  1. Confirm one or more of the above listed incidents occur
  2. Replace the BCM with the countermeasure part.
  3. The ADP system must be initialized anytime the BCM or the battery is replaced. Perform the following procedure:
    1. Insert the key into the ignition switch.
    2. Open, close, then open the driver's side door.
    3. Make sure the ADP automatic mode is functioning properly.
  4. Refer to the EL section of the appropriate service manual, or the INFINITINET Technical Information Sub-System for electrical incidents that are unrelated to the LAN system.

PARTS INFORMATION

PARTS INFORMATION

Description P/N / PFP Qty
Control Assembly - LAN (BCM) 28491-67U04 1

CLAIMS INFORMATION

Submit a Primary Failed Part (PFP) claim using the following coding:

CLAIMS INFORMATION

Operation OP Code SYM DIAG FRT PFP
RPL Body Control Module RD94AA ZE (1) 32 0.3 hrs 28491-67U04
(1) Or as symptom indicates.