Park/Neutral Position Relay

Check continuity between terminals (6) and (7).

PARK/NEUTRAL POSITION RELAY CONDITION AND CONTINUITY SPECIFICATIONS

Condition Continuity
12V direct current supply between terminals (1) and (2). Yes
No current supply No
Fig 1: Checking Continuity Between Park/Neutral Position Relay Terminals
G02843044