Door Lock/Unlock Switch LH Check
- CHECK DOOR LOCK/UNLOCK SWITCH INPUT SIGNAL
- Disconnect smart entrance control unit connector.
- Check continuity between control unit terminal 23 or 35 and ground.
DOOR LOCK/UNLOCK SWITCH CONTINUITY SPECIFICATIONSTerminals Door lock/unlock switch (LH or RH) condition Continuity 23 - ground Lock Yes N and Unlock No 35 - ground Unlock Yes N and Lock No Refer to wiring diagram in Wiring Diagram - MULTI- .
OK or NG
- OK Door lock/unlock switch is OK.
- NG GO TO 2.
- CHECK DOOR LOCK/UNLOCK SWITCH
- Disconnect door lock/unlock switch connector.
- Check continuity between each door lock/unlock switch terminals.
Power window main switch (Door lock/unlock switch LH)
DOOR LOCK/UNLOCK SWITCH CONTINUITY SPECIFICATIONSCondition Continuity Between Terminals Lock 5 & 6 N No continuity Unlock 5 & 19 OK or NG
- OK Check the following.
Ground circuit for door lock/unlock switch
Harness for open or short between door lock/unlock switch and smart entrance control unit connector
- NG Replace door lock/unlock switch.