FixVault

Work Flow

  1. CHECK WARNING LAMPS 
    1. Turn ignition switch ON.
    2. Warning lamps should illuminate (seat belt warning or door warning etc.).

    Do warning lamps illuminate? 

    1. YES >> GO TO 2
    2. NO >> Power supply and ground check. Refer to POWER SUPPLY AND GROUND CIRCUIT CHECK  .
  2. CHECK INDICATOR LAMPS 

    Meter/gauges/A/T indicator should indicate.

    Do indicators indicate? 

    1. YES >> GO TO 3
    2. NO >> Fluorescent lamp check. Refer to FLUORESCENT LAMP CHECK  .
  3. CHECK SELF-DIAGNOSIS MODE OPERATION 

    Preform self-diagnosis mode. Refer to METER/GAUGES OPERATION, ODO/TRIP METER AND A/T INDICATOR  Can diagnosis mode be activated?

    1. YES >> GO TO 4
    2. NO >> Replace unified meter control unit (sub)
  4. SEGMENTS CHECK 

    Check odo / trip meter segment or A/T indicator segment.

    Do all segments illuminate? 

    1. YES >> GO TO 5
    2. NO >>
  5. CHECK SELF-DIAGNOSIS MODE 

    Check meter / gauge operation in self-diagnosis mode. Refer toMETER/GAUGES OPERATION, ODO/TRIP METER AND A/T INDICATOR  .

    OK or NG 

    1. OK >> Symptom chart 2
    2. NG >> Symptom chart 1