FixVault

Check Stop Lamp Switch

  1. STOP LAMP SWITCH POWER SUPPLY CIRCUIT INSPECTION 
    1. Disconnect stop lamp switch connector.
    2. Check voltage between stop lamp switch connector E210 terminal 1 (GY) and ground.

      1 (GY) and ground: Battery voltage 

    OK or NG

    1. OK: GO TO 2.
    2. NG: Repair or replace harness between stop lamp switch and fuse.
      Fig 1: Inspecting Stop Lamp Switch Power Supply Circuit
      G03107078Courtesy of NISSAN MOTOR CO., U.S.A.
  2. STOP LAMP SWITCH OPERATION INSPECTION 

    Check continuity between stop lamp switch connector E210 terminal 1 and 2.

    1-2 

    Brake pedal depressed: Continuity should exist. 

    Brake pedal not depressed: Continuity should not exist. 

    OK or NG

    1. OK: GO TO 3.
    2. NG: Replace stop lamp switch.
      Fig 2: Inspecting Stop Lamp Switch Operation
      G03107079Courtesy of NISSAN MOTOR CO., U.S.A.
  3. STOP LAMP SWITCH GROUND CIRCUIT INSPECTION 
    1. Check continuity between stop lamp switch connector E210 terminal 2 (P) and intelligent Key unit connector M34 terminal 26 (P/L).

      2 (P)-26(P\L):Continuity should exist. 

    2. Check continuity between stop lamp switch connector E210 terminal 2 (P) and ground.

      2(P)- Ground: Continuity should not exist. 

    OK or NG

    1. OK: Stop lamp switch is OK.
    2. NG: Repair or replace harness.