FixVault

Solenoid Valve Operation Chart

SOLENOID VALVE OPERATION

Operation ABS solenoid valve ABS solenoid valve (ACT)
UP KEEP DOWN UP ACTUATOR UP ACTUATOR KEEP
FR RH IN SOL OFF ON ON OFF OFF OFF
FRRHOUTSOL OFF OFF ON(1) OFF OFF OFF
FR LH IN SOL OFF ON ON OFF OFF OFF
FR LH OUT SOL OFF OFF ON(1) OFF OFF OFF
RR RH IN SOL OFF ON ON OFF OFF OFF
RR RH OUT SOL OFF OFF ON(1) OFF OFF OFF
RR LH IN SOL OFF ON ON OFF OFF OFF
RR LH OUT SOL OFF OFF ON(1) OFF OFF OFF
Primary side VDC switch over valve 1 (SV 1) OFF OFF OFF OFF ON(1) OFF
Primary side VDC switch over valve 1 (CV 1) OFF OFF OFF OFF ON ON
Secondary side VDC switch over valve 2 (SV 2) OFF OFF OFF OFF ON(1) OFF
Secondary side VDC switch over valve 2 (CV 2) OFF OFF OFF OFF ON ON
(1) ON for 1 to 2 seconds after the touch, and then OFF
NOTE:
  • If active test is performed with brake pedal depressed, pedal stroke may change. This is normal.
  • "TEST IS STOPPED" is displayed approximately 10 seconds after operation starts.
  • After "TEST IS STOPPED" is displayed, touch "BACK" and conduct the test from the Step  8.