FixVault

4. Check Back Door Closure Control Unit Output Signal

  1. Connect back door closure control unit connector.
  2. Check voltage between back door closure control unit connector D106 terminal 5 and ground.
    Fig 1: Checking Voltage Between Back Door Closure Control Unit Connector D106 Terminal 5 And Ground
    G00724820Courtesy of NISSAN MOTOR CO., U.S.A.
    1. 5 (W) - Ground : Approx. 5V 

OK or NG

OK : Replace front door lock assembly (passenger side).

NG : Replace back door closure control unit.