FixVault

Knock Sensor

Check resistance between knock sensor terminal 1 and ground.

NOTE: It is necessary to use an ohmmeter which can measure more than 10 Mohm.
  1. Resistance: Approximately 532 - 588 kohm [at 20° C (68° F)] 
CAUTION: Do not use any knock sensors that have been dropped or physically damaged. Use only new ones.
Fig 1: Checking Knock Sensor Resistance
G00344907Courtesy of NISSAN MOTOR CO., U.S.A.