5. Check EVAP Control System Pressure Sensor Ground Circuit For Open And Short

WARNING: This page is about a different variant/trim than selected.
  1. Turn ignition switch OFF.
  2. Disconnect ECM harness connector.
  3. Check harness continuity between EVAP control system pressure sensor terminal 1 and ECM terminal 67.

    Refer to Wiring Diagram.

    1. Continuity should exist. 
  4. Also check harness for short to ground and short to power.

OK or NG 

OK: GO TO 7 .