FixVault

Checking And Adjusting: Notes

WARNING: This page is about a different car, the 2003 Infiniti I35. However, it is still accessible from the selected car via links, so may be relevant.

Adjust the lubricant quantity according to the test group shown below.

  1. Check Lubricant Return Operation 

    Can lubricant return operation be performed?

    • A/C system works properly.
    • There is no evidence of a large amount of lubricant leakage.
    1. Yes or No 

    Yes: Go to next step.

    No: Go to step  3.

  2. Perform Lubricant Return Operation, Proceeding As Follows  :
    1. Start engine, and set the following conditions:

      Test condition Engine speed: Idling to 1,200 RPM 

      AUTO switch: ON 

      Blower speed: Max. Position 

      Temp. Control: Optional [Set so that intake air temperature is 25 to 30°C (77 to 86°F).] 

    2. Next item is for V-6 compressor. Connect the manifold gauge, and check that the high pressure side pressure is 588 kPa (6 kg/cm 2  , 85 psi) or higher. 

      If less than the reference level, attach a cover to the front face of the condenser to raise the pressure. 

    3. Perform lubricant return operation for about 10 minutes.
    4. Stop engine.
    CAUTION: If excessive lubricant leakage is noted, do not perform the lubricant return operation.

    OK: Go to next step.

  3. Check Compressor 

    Should the compressor be replaced?

    1. Yes or No 

    Yes: Go to LUBRICANT ADJUSTMENT PROCEDURE FOR COMPRESSOR REPLACEMENT .

    No: Go to next step.

  4. Check Any Part 

    Is there any part to be replaced? (Evaporator, condenser, liquid tank or in case there is evidence of a large amount of lubricant leakage.)

    1. Yes or No 

    Yes: Go to LUBRICANT ADJUSTING PROCEDURE FOR COMPONENTS REPLACEMENT EXCEPT COMPRESSOR .

    No: Carry out the A/C performance test.